Comments on: Boiler Water Treatment in Marine Boilers https://shipfever.com/boiler-water-treatment-marine/ We here at ShipFever brings the quality content to you. The content written here cannot be found in any Marine Book, and are work of experience, with simplified diagrams explained is simple term. Wed, 02 Jun 2021 05:44:00 +0000 hourly 1 https://wordpress.org/?v=6.8.8 By: RIJU BHATNAGAR https://shipfever.com/boiler-water-treatment-marine/#comment-20360 Wed, 02 Jun 2021 05:44:00 +0000 https://shipfever.com/?p=534#comment-20360 Exhaust Gas Boiler is mostly tubular of less diameter, by design with little additional thickness it can withstand much higher pressure ( for F.O.S 2, material stress*30% = PD/2t). Exhaust gas Boiler recirculating pump takes Boiler water from condenser on circulation through Exhaust Gas Boiler, needs higher pressure & flow to pick up the heat ( as internal volume of the Exhaust Boiler is quite less compared with the main boiler) and delivers to deaerator. Hence Exh Gas boiler needs to be at a higher pressure

]]>
By: Sanoor Kaviraj Shetty https://shipfever.com/boiler-water-treatment-marine/#comment-15897 Fri, 01 Jan 2021 11:33:32 +0000 https://shipfever.com/?p=534#comment-15897 EGB safety valave is to be set at higher pressure than boiler safety valve because if EGB safety valve setting is less, then how the boiler water circulating pump can put water inside the boiler whose inside pressure is already 6 bar so to put water inside the boiler your pump pressure should be more than 6 bar so according to that your EGB safety valave setting is more

]]>
By: Amit Abhishek https://shipfever.com/boiler-water-treatment-marine/#comment-14514 Wed, 18 Nov 2020 11:52:10 +0000 https://shipfever.com/?p=534#comment-14514 In reply to Mohammed Khan.

First, the safety valve of the boiler should lift so that the water flow in the economizer should not stop in case of high pressure or else tubes of economizer will burn due to lack of water flow.

]]>
By: Mohammed Khan https://shipfever.com/boiler-water-treatment-marine/#comment-14497 Wed, 18 Nov 2020 03:35:39 +0000 https://shipfever.com/?p=534#comment-14497 Dear Sir,

Above article was very informative. I am an old time Chief Engineer, presently a faculty member of a teaching college.

I have a question. Can you tell me the “reasons as to why Exhaust Gast Economiser Safety Valve setting is set at a slightly higher pressure than the Auxiliary Boiler’s Safety Valve setting?”

i know for sure it is set at a higher setting; but for what reasons I do not know!

And also by how much % more than the Aux. Blr. Safety Valve.

I am very happy that nowadays there are so many marine sites helping students. In our days there were only books, which we could’n’t afford, and very few marine colleges and that too only in big cities.

I appreciate all your hard work and I wish you success in all your endeavour.

Thanking You,
With warm regards,
Mohammed Khan
Ex-Chief Engineer
emkaysails@yahoo.com

]]>